Rebar corrosion detection XS100

SOUTHGEOSYSTEMS
XS-100-A300950
ex Shipping kg
Add to cart
  • Description
  • More
  • Specifications

Rebar corrosion detection XS100

Rebar corrosion detection

1.Easy to operate, fast and accurate read. The result is displayed with numbers or graphics.

2.Displays rebar corrosion degree with 9-level grey or colorful graphics

3.Measured data is inputted to PC software from USB interface.

4.Easy to operate, have concise software interface, have powerful analytical processing, can obtain testing report directly.

Brief introduction

XS-100 rebar corrosion detection is NDT instrument which tests rebar corrosion in the concrete structure. Using electrochemistry method, do the functions for corrosion detection, data analysis, storage and output etc. It is a detection instrument which is handed, measurement accurately and easy to use.

Standard configuration

Main Unit,
Signal transmission line,
Lateral device,
USB data line,
Clamp,
Manual,
Software

Rebar Corrosion System En

Number

Items

SPEC

1

Potential electrode

Φ37X127mm

2

Electrode weight

200g

3

Power supply

Alkaline cell X 6

4

Potential measurement range

±1000mv

5

Test Accuracy

1mv

6

Distance of test point

0 - 1000mm

7

Data storage capacity

50000 test points,5000test areas

8

Usage temperature range

-10 - 40

9

Size

220*145*60mm